Brand Name : Rexroth
Model Number : A2FO107/61R-NBD55 A2FO107/61R-PPB05 A2FO107/61R-VPB05 A2FO107/61R-VSD55 A2FO107/61L-VSD55
Certification : ISO
Place of Origin : German
MOQ : 1
Price : 2
Payment Terms : MoneyGram,Western Union,T/T,D/P,D/A,L/C
Supply Ability : 100
Delivery Time : 2 weeks
Packaging Details : wooden box
whatsapp : +85267220981
Inlet Connection : Threaded or Flanged
Shaft Type : Keyed shaft
Application : Mobile and industrial hydraulic systems
Power : Hydraulic
Maximum Pressure : 315 bar
Delivery Date : 5 days
Structure : PISTON PUMP
Direction Of Rotation : Clockwise or counterclockwise
Usage : Oil
Certifisaarion : ISO9001
Control Type : Variable displacement axial piston pump
A2FO107/61R-NBD55
A2FO107/61R-PPB05
A2FO107/61R-VPB05
A2FO107/61R-VSD55
A2FO107/61L-VSD55 Industrial engineering machinery arm pump German Rexroth plunger pump A2FO107 hydraulic motor
| whatsapp: | +85267220981 | Email: | Yli97584@mail.com |
| maximum load: | 350MPA | speed regulation range: | 250L/min |
| control form: | Hydraulic Control | Applicable Industries: | Machinery, Heavy Industry |
| Applicable Machinery: | injection molding machine | test scope: | 180-680 |
| degree of newness: | brand new | brand: | Rexroth |
| Model: | A2FO107/61R-NBD55 A2FO107/61R-PPB05 A2FO107/61R-VPB05 A2FO107/61R-VSD55 A2FO107/61L-VSD55 | Packing: | wooden box |

| A2FO107/61L-PZB05 |
| A2FO107/61L-VAB05 |
| A2FO107/61L-VAB05 |
| A2FO107/61L-VBB05 |
| A2FO107/61L-VBB05 |
| A2FO107/61L-VBB05 |
| A2FO107/61L-VBB05-S |
| A2FO107/61L-VBB05-S |
| A2FO107/61L-VPB05 |
| A2FO107/61L-VPB05 |
| A2FO107/61L-VPB05 |
| A2FO107/61L-VPB05-S |
| A2FO107/61L-VPB05-S |
| A2FO107/61R-NBB050 |
| A2FO107/61R-PAB05 |
| A2FO107/61R-PAB05 |
| A2FO107/61R-PAB050 |
| A2FO107/61R-PBB05 |
| A2FO107/61R-PBB05 |
| A2FO107/61R-PBB05 |
| A2FO107/61R-PBB05 |
| A2FO107/61R-PBB05 |
| A2FO107/61R-PPB05 |
| A2FO107/61R-PPB05 |
| A2FO107/61R-PPB05 |
| A2FO107/61R-PPB05 |
| A2FO107/61R-PPB05 |
| A2FO107/61R-PPB05 |
| A2FO107/61R-PPB05-S |
| A2FO107/61R-PPB105 |
| A2FO107/61R-PSB05-S |
| A2FO107/61R-PZB05 |
| A2FO107/61R-PZB05 |
| A2FO107/61R-VAB05 |
| A2FO107/61R-VAB05 |
| A2FO107/61R-VAB05-S |
| A2FO107/61R-VBB05 |
| A2FO107/61R-VBB05 |
| A2FO107/61R-VBB05 |
| A2FO107/61R-VBB05-S |
| A2FO107/61R-VBB05-S |
| A2FO107/61R-VPB05 |
| A2FO107/61R-VPB05 |
| A2FO107/61R-VPB05 |
| A2FO107/61R-VPB05-S |
| A2FO107/61R-VPB05-S |
| A2FO107/61R-VZB05 |
| A2FO107/61R-VZB05 |
| AA2FO107/61L-VBD55 |
| AA2FO107/61L-VBD55 |
| AA2FO107/61L-VSD55 |
| AA2FO107/61L-VSD55 |
| AA2FO107/61L-VSD55 |
| AA2FO107/61R-NBD55 |
| AA2FO107/61R-NUD55 |
| AA2FO107/61R-VSD55 |
| A2FO125/61L-PAB05 |
| A2FO125/61L-PAB05 |
| A2FO125/61L-PAB05 |
| A2FO125/61L-PBB05 |
FAQ:
维护与保养 (Maintenance & Servicing)
• Q: What routine maintenance does the A2FO56 pump require?
◦ A: Proper maintenance is crucial for longevity and reliable operation. Key practices include :
▪ Pre-Startup Check: Verify oil level in the tank before startup. Use the recommended grade of hydraulic fluid .
▪ Initial Run: After a shutdown of more than 4 hours, allow the pump to run without load for at least 5 minutes before applying pressure .
▪ Regular Monitoring: Consistently check operating parameters like pressure, speed, and, importantly, oil temperature during work. The optimal operating oil temperature is typically suggested to be between 35°C and 60°C. If a sudden temperature rise occurs, investigate the cause immediately .
▪ Inspection: Regularly check pipe joints and flange connections for tightness to prevent leaks and air ingress .
▪ Oil Cleanliness: Maintain the cleanliness of the hydraulic oil. The higher the oil cleanliness, the longer the service life of the pump. External contaminants must be prevented from entering the reservoir and the pump .
• Q: What should I do if the pump's flow rate is insufficient or performance drops?
◦ A: Potential causes based on common issues include :
▪ Low Drive Speed: Ensure the motor meets the pump's required rated speed.
▪ Leaks in the System: Check the system for and repair any leakage points.
▪ Aeration/Suction Problems: Inspect the suction line for air leaks. Ensure the oil level in the tank is not too low.
▪ Loose Pump Casing Bolts: Prolonged operation and vibration can loosen bolts, which may need tightening to specification.
4. 售后服务,保修与贴牌 (After-Sales Service, Warranty & OEM)
• Q: What is the warranty policy for these pumps?
◦ A: Some suppliers offer a 12-month quality guarantee for their hydraulic pumps and motors. It is essential to confirm the specific warranty terms with your supplier or distributor at the time of purchase .
• Q: Is OEM (Original Equipment Manufacturer) service or private labeling available?
◦ A: Yes, certain manufacturers and suppliers explicitly state that they accept OEM requests and can mark products with your brand and product codes. This service is typically available for all products .
• Q: What about after-sales support and spare parts?
◦ A: Many suppliers position themselves as specialists providing system integration, technical support, and maintenance services. They often stock commonly used spare parts like piston pumps, vane pumps, and gear pumps to support customer needs . It is advisable to choose a reputable distributor or direct agent for better technical support and service .
5. 应用与安全 (Application & Safety)
• Q: What are the typical applications for the A2FO56 pump?
◦ A: This series is widely used in various machinery, including :
▪ Mobile Machinery: Concrete truck mixers, cranes (e.g., from manufacturers like XCMG, SANY), and other construction equipment.
▪ Industrial Applications: Various stationary industrial hydraulic systems.
• Q: Are there important safety instructions for installation and operation?
◦ A: Critical safety instructions include :
▪ The axial piston unit must always be filled with hydraulic oil and vented before commissioning and operation.
▪ The case drain line must be connected separately to the tank, ensuring it is below the low oil level and that the specified maximum case pressure is not exceeded.
▪ The minimum inlet pressure at port S (suction) must not fall below 0.8 bar absolute during operation to prevent cavitation.
▪ Use flexible connections for piping to achieve favorable noise values.
|
|